Ficha Técnicas NoBreak TRIPP LITE 6000VA SU6000RT4U click aquí
Tiempo de Respaldo NoBreak TRIPP LITE 6000VA SU6000RT4U click aquí
Manual de Usuario NoBreak TRIPP LITE 6000VA SU6000RT4U click aquí
Link a la pagina del Fabricante click aquí
Tripp Lite 6kVA SmartOnline Hot-Swappable Modular Rack/Tower
UPS. 6000VA on-line, double-conversion UPS for server, network and
telecommunications equipment. Maintains battery-derived AC output during
blackouts with active, full-time power conditioning. Fault-tolerant
auto-bypass prevents unexpected service interruptions during overload or
internal fault conditions. Single all-in-one housing installs in 4 rack
spaces (4U). Upright tower installation with optional 2-9USTAND accessory. 2
post rackmount installation with optional 2POSTRMKITWM. Full-time sine wave
output within 3% of selectable 208/120 or 240/120V AC. Corrects brownouts
and overvoltages from 65V to 140V (L-N). Expandable runtime with optional
external battery packs. Converts raw input from AC to DC, then back to
perfect sine wave AC output with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems
not addressed by other UPS types. Highly efficient operation in optional
economy mode setting, saving BTU heat output and energy costs. Network-grade
AC surge and noise suppression. Network management interfaces include
combination RS-232 enabled and contact closure serial port, enhanced USB
port and SNMPWEBCARD slot. Includes USB and DB9 serial ports. Built-in DB9
port offers both enhanced RS-232 enabled monitoring data, plus contact
closure monitoring ability. HID-compliant USB interface enables integration
with built-in power management and auto shutdown features of Windows and Mac
OS X. Supports simultaneous detailed monitoring of equipment load levels,
self-test data and utility power conditions via all 3 network interfaces.
Includes PowerAlert monitoring software and complete cabling. Emergency
Power Off (EPO) interface. Front panel LEDs and LCD readout with scroll
controls support visual monitoring of all major UPS functions. LED/LCD
display panel easily rotates for viewing in rackmount or tower
configurations. Audible alarm. Self test. 4-post rackmount accessories.
L14-30P split phase 4 wire plug-in connection: two L6-30R, two L6-20R and
eight 5-15/20R output receptacles. Input cord and outlets are mounted on a
detachable backplate with manual bypass switch to enable hot-swappable UPS
replacement without powering off connected equipment. Optional SUPDM56HW
installable backplate accessory enables hardwire input-output connections.
Optional external Power Distribution Unit (PDU) options available. Internal
batteries and optional external battery packs are field replaceable and hot
swappable. Attractive all-black color scheme. 2-year warranty and $250,000
connected equipment insurance; extended warranty and service contracts
available.
* True online, double-conversion UPS provides pure, full-time sine wave AC
output free of surges, voltage fluctuations and line noise
* 6000VA/4200 watt output power capacity with dual voltage output of 208/120
or 240/120V
* 4U all-in-one high power density housing supports rackmount installation
in only 4 rack spaces
* Dual conversion UPS actively converts raw input from AC to DC, then back
to perfect sine wave AC output with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems
not addressed by other UPS types
* Input cord and outlets are mounted on a detachable backplate with manual
bypass switch to enable hot-swappable UPS replacement without powering off
connected equipment
* Optional SUPDM56HW and SUPDMB568HW installable backplate accessories
enable hardwire input-output connections
* Provides perfectly regulated, sine wave output power free of line noise,
transient surges and frequency variation for the most efficient operation of
critical servers, networking and telecommunications equipment
* Maintains output within 3% of selected 208/120 or 240/120V nominal voltage
during brownouts and overvoltages
* Supports connected equipment during blackouts for 20/8 minutes at half/full
load levels, runtime is further expandable with optional external battery
packs
* Network interfaces support simultaneous communications via DB9 port, USB
port and SNMPWEBCARD slot
* Included PowerAlert UPS monitoring software supports safe unattended
shutdown, monitoring and control via local connected servers, plus any
number of additional servers over IP
* Communications ports support on-battery, low-battery, power-restored, AC-voltage,
DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test and
output power control
* Includes USB and DB9 serial ports. Built-in DB9 port offers both enhanced
RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant
USB interface enables integration with built-in power management and auto
shutdown features of Windows and Mac OS X.
* Built-in Emergency Power Off (EPO) interface with cable
* Includes 12 built-in output receptacles (2 L6-30R, 2 L6-20R, 8 NEMA
5-15/20R)
* L14-30P split phase, 4 wire plug-in connection (featured on included
detachable PDU). Optional SUPDM56HW hardwire input/output PDU available
separately
* Front panel LEDs and LCD readout with scroll button enables visual
confirmation of all major UPS functions and current site electrical
conditions
* Front panel switches enable power on/off control, self-test and alarm
cancel functions
* Included adjustable mounting rails support installation in 4 post 19 inch
rack enclosures
* Optional 2-9USTAND set of tower stands supports upright tower installation
* Optional 2POSTRMKITWM accessory enables 2 post rackmount installation
* UPS ships fully assembled in full compliance with DOT regulations, no time
consuming connection of internal batteries by user is required
* Fault-tolerant auto-bypass maintains continuous utility output to
connected equipment, even in cases where the UPS is overloaded or suffers an
internal failure that requires service
* Detachable PDU with built-in manual bypass switch enables hot-swappable
UPS replacement without powering off connected equipment
* 2 year manufacturer's product warranty, $250,000 Ultimate Lifetime
Insurance (USA & Canada only)
Incluído en el Empaque
* Sistema UPS SU6000RT4U (con md0075006co PDU SUPDMB56 desmontable)
* Cableado USB, DB9 y EPO
* Equipo de instalacin00200070ara montar en rack de 4 puestos
* Manual del propietario e informacin00200073obre la garanta003c/li>
DESCRIPCIÓN NOBREAK TRIPP
LITE 6000VA SMARTONLINE SU6000RT4U
SALIDA
Capacidad de salida voltios amperios (VA) 6000
2000 6
Capacidad de salida vatios (vatios) 4200
2000 4.2
Output power factor 0.7
2000 6,000 VA (240V) / 5400 VA (208V) / 4200 watts (208/240V)
2400 3:1
Voltaje(s) nominal de salida soportado 120v; 208v; 240v
2400 240/120 or 208/120 split phase output
Compatibilidad de frecuencia 60Hz
Regulación de la tensión de salida (modo línea) +/- 3%
2500 +/- 10%
Regulación del voltaje de salida (modo batería) +/- 3%
Receptáculos de salida UPS incorporados 8 5-15/20R outlet(s); 2 L6-20R
outlet(s); 2 L6-30R outlet(s)
Disyuntor de salida 20A branch rated breakers (x4) protect 2 5-15/20R
outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R
outlets are unbreakered
2880 PDU1220 (1U / 13 5-15/20R outlets); PDU1230 (1U / 2 C19, 16 C13 outlets);
PDUNV (1U / 2 C19, 12 C13 outlets); PDUV30HV (0U / 6 C19, 32 C13 outlets)
3000 PDUMH20 (1U / 13 5-15/20R outlets); PDUMH20AT (1U / 16 5-15/20R outlets)*;
PDUMV20 (0U / 16 5-15/20R outlets); PDUMV40 (0U / 32 5-15/20R outlets);
PDUMV20HV (0U / 6 C19, 32 C13 outlets); PDUMV30HV (0U / 6 C19, 24 C13
outlets) PDUMH20ATNET (1U / 16 5-15/20R outlets)*; PDUMH20HVNET (1U / 8 C13
outlets); PDUMH30HVNET (2U / 16 C13 outlets); PDUMV20NET (0U / 24 5-15/20R
outlets); PDUMV20HVNET (0U / 4 C19, 24 C13 outlets); PDUMV30HVNET (0U / 4
C19, 24 C13 outlets)
Forma de onda a la salida (en modo línea) Sine wave
Forma de onda a la salida (en modo respaldo de batería / inversor) Sine wave
ENTRADA
Corriente de entrada clasificada (a carga máxima) 24A
Voltaje(s) nominal(es) de entrada soportado(s) 208V AC / 120V AC (4 wire
split single phase); 240V AC /120V AC (4 wire split single phase)
Tipo de conexión de entrada UPS L14-30P
4000 4 wire split-phase input (L1, L2, N, G)
Longitud del cable de entrada del UPS (pies) 10
Longitud del cable de entrada del UPS (m) 3
Servicio eléctrico recomendado Fase dividida de 30A 208/120V
Longitud del cable de entrada (pies) 10
Longitud del cable de entrada (mt) 3
BATERÍA
Autonomía con carga completa (minutos) 8 min. (4200w)
Autonomía con media carga (minutos) 20 min. (2100w)
Autonomía de batería expandible Supports extended runtime with optional
external battery packs
Compatibilidad con paquete de batería externo BP192V12-3U; BP192V557C-1PH;
BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH
Tensión del sistema de CC 192V CD
Velocidad de recarga de la batería (baterías incluidas) Less than 6 hours
from 10% to 80%
Cartucho de batería de sustitución (batería interna UPS) RBC9-192
Accesso a la batería Puerta de acceso a la batera0020en el panel frontal
Descripción del reemplazo de la batería Hot-swappable, user replaceable
batteries
REGULACIÓN DE VOLTAJE
Descripción de la regulación de tensión Acondicionamiento de la
energa0020de doble conversin002c0020en ln0065a
Corrección de sobretensión 3% output voltage regulation during overvoltages
to 140 (measured L1-N : L2-N)
Corrección de baja tensión 2% output voltage regulation during undervoltages
to 65 (measured L1-N : L2-N)
ALARMAS DE LED E INTERRUPTORES
Indicadores LED 6 LEDs indicate line power, online mode, economy/bypass
mode, on-battery, charger and AC output status; LCD screen offers additional
information and control options
Alarmas Alarmas sonoras exclusivas para la mayora0020de los UPS, condiciones
ambientales y energt0069cas (consulte el manual)
Operación para cancelar (silenciar) la alarma Alarm cancel switch
Interruptores (botones) Incluye un interruptor principal de
apagado/encendido, ms00202 interruptores para configurar y ejecutar
funciones LCD de desplazamiento. Un interruptor de derivacin0020006danual
incluido en la PDU desmontable permite la extraccin00200063ompleta del UPS
durante el mantenimiento de rutina sin interrumpir la alimentacin00200064e
las cargas conectadas. El interruptor nivel de carga de la batera0020permite
ajustar la salida del cargador a una velocidad de carga superior cuando se
agregan md0075006cos de batera0073 externas.
SUPRESIÓN DE SOBRECARGA / RUIDO
Tiempo de respuesta de supresión de CA del UPS Instantaneous
Supresión de ruido CA EMI / RFI S�0000
Tiempo de respuesta de supresión de CA Instantn0065o
FÍSICAS
Factores de forma de instalación soportados incluidos 4 post 19 inch
rackmount (mounting rail kit included)
Factores de forma de instalación soportados con opcional 2 post rackmount
(2POSTRMKITWM); Tower (2-9USTAND)
Forma de instalación primaria Rackmount
UPS/ Dimensiones del módulo eléctrico en factor de forma primario 7 x 17.5 x
30.8 17.8 x 44.4 x 78.1
05/05/10 30.8
19/05/10 78.1
Altura del espacio en rack total del sistema completo instalado 4U
Secondary form factor Tower (requires 2-9USTAND)
Installed whole system dimensions in secondary form factor (height x width x
depth / inches) 17.5 x 7 x 30.8
UPS dimensions in secondary form factor (height x width x depth / cm) 44.4 x
17.8 x 78.1
UPS / Peso del módulo eléctrico (libras) 149.6
UPS / Peso del módulo eléctrico (kilogramos) 67.9
Detalles de las dimensiones del UPS 4U UPS with internal batteries
Dimensiones de envío UPS (altura x anchura x profundidad / 13.2 x 37 x 23
33.7 x 94 x 58.4
Peso de envío (libras) 189.2
Peso de envío (kg) 85.9
Material de la carcasa UPS Steel
Método de enfriamiento Ventilador
AMBIENTALES
Rango de temperatura operativa +32 to +104 degrees Fahrenheit / 0 to +40
degrees Celsius
Rango de temperatura de almacenamiento +5 to +122 degrees Fahrenheit / -15
to +50 degrees Celsius
Humedad relativa 0 a 95%, sin condensacin002e0000
CA modo BTU / hr. (carga completa) 1586.7
Modo batería BTU / hr. (carga completa) 1412.3
Elevación operativa (pies) 0 a 3000 m (0 a 10.000 pies).
Ruido audible 60 dBA at front side 1 meter
COMUNICACIONES
Interfaz de comunicaciones USB (HID enabled); DB9 Serial; Contact
closure; EPO (emergency power off); Slot for SNMP/Web interface
Descripción del puerto de monitoreo de la red RS232 and contact closure
communications are supported on one DB9 port
Software PowerAlert de Tripp Lite Included
Cable de comunicación USB and DB9 cabling included
TIEMPO DE TRANSFERENCIA LÍNEA / BATERÍA
Tiempo de transferencia No transfer time (0 ms.) in online, double-conversion
mode
Transferencia de baja tensión a la energía de la batería (punto de ajuste)
65V (L1-N:L2-N)
Transferencia de alta tensión a la energía de la batería (punto de ajuste)
140V (L1-N:L2-N)
FUNCIONES ESPECIALES
Arranque en frío (puesta en marcha en modo batería durante un
Tensión) Cold-start operation supported
Características de alta disponiblidad Automatic inverter bypass; Manual
bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot
swappable batteries
Funciones ecológica y de alta eficiencia High efficiency economy mode
operation; Schedulable daily hours of economy mode operation
CERTIFICACIONES
Certificaciones del UPS Tested to UL1778 (USA); Tested to CSA (Canada);
Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ROHS (Reduction
of Hazardous Substances)
GARANTÍA
Período de garantía del producto 2 ao00730000
Cobertura del equipo conectado Seguro para los equipos conectados de
$250.000,00
|