Tripp Lite's SMART1500LCD Line-Interactive Digital UPS
System offers voltage regulation, surge suppression and long-lasting battery
support for personal computers, network workstations, home entertainment
systems and media centers. Internal UPS circuits support entry-level PCs or
individual VCR/DVR components during power failures. Prevents data loss,
viewing interruptions, lost recordings and loss of component programming.
Automatic Voltage Regulation (AVR) circuits regulate brownouts and
overvoltages from 75V to 147V back to usable levels without using battery
power. Offers complete power protection with support for upright tower, flat
shelfmount or 2U rackmount installation in an attractive all-black cabinet
design. Includes 8 battery-supported outlets. Built-in USB and DB9 serial
port enables optional unattended system shutdown without data loss in case
of extended power failure; cabling included. PowerAlert software available
via free download from www.tripplite.com. HID-compliant USB interface
enables integration with built-in power management and auto shutdown
features of Windows and Mac OS X. Built-in single-line RJ-45 jacks offer
protection for equipment with single-line tel/DSL or network Ethernet
connection. Built-in audible alarm and large LCD front panel voltage display
indicates line power status, battery power status, battery low/replace
status and voltage boost operation. The LCD display includes a dimmer switch
and can be rotated for easy viewing in any application. 1500VA/900W power-handling
capacity supports entry-level PCs, home entertainment systems, network
workstations and audio/video components. Offers 3.5 minutes battery runtime
with a full load of 1500VA/900W and 13 minutes with a half load of
750VA/450W. 3-year warranty; $250,000 connected equipment insurance (USA &
Canada only).
Key Features
* LCD Display indicates input voltage, battery capacity and a variety of
operating conditions. Display is rotatable for easy viewing whether UPS is
in vertical or horizontal position
* SMART1500LCD Digital Uninterruptible Power Supply offers voltage
regulation, surge suppression and long-lasting battery support during
blackouts
* Supports entry-level PCs or single VCR/DVR components during blackouts
* Regulates brownouts and overvoltages from 75V to 147V back to usable
levels without using battery power
* 8 UPS battery-supported outlets
* Included DB9 serial and USB monitoring port and cable enables unattended
shutdown in the case of extended power failure
* HID-compliant USB port enables full integration with built-in power
management and auto shutdown features of Windows and Mac OS X
* PowerAlert software available via free download from www.tripplite.com
* Set of phone/network protection jacks protects a single dialup/DSL phone
line or network Ethernet connection
* 1500VA/900W power handling ability supports a variety of sensitive
computer, home theater and other equipment
* 3.5 min. full load runtime (1500VA/900W); 13 min. half-load runtime
(750VA/450W)
* Cabinet adapts to tower or rackmount shelf format. Rackmount installation
brackets for 2U installation included
* 3-year product warranty
* $250,000 connected equipment insurance (USA & Canada Only).
Package Includes
* SMART1500LCD Digital UPS
* USB and phone cabling
* Mounting hardware
* Manual with warranty information
DESCRIPCIÓN NOBREAK TRIPP
LITE 1500VA SMARTPRO1500LCD
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output kVA capacity (kVA) 1.5
Output Watt Capacity (watts) 900
Nominal Output Voltage(s) Supported 115v; 120v
Frequency compatibility 60 Hz
Output voltage regulation (line mode) -18%, +8%
Output voltage regulation (Battery mode) 115V (+/- 5%)
Built-in UPS output receptacles 8 5-15R outlet(s)
Basic PDU options PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13
outlets); PDU1415 (0U / 14 5-15R outlets); PDUV15 (0U / 12 5-15R outlets)
Metered PDU options PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R
outlets)*; PDUMV15 (0U / 16 5-15R outlets)
Switched PDU options PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U /
16 5-15R outlets)
External PDU redundancy options *Auto Transfer Switch features utilizing the
secondary PDU input cord are compatible with Smart Online UPS models only
Output AC waveform (AC mode) Sine wave
Output AC waveform (battery mode) PWM sine wave
INPUT
Rated input current (at maximum load) 8.5A
Nominal Input Voltage(s) Supported 120V AC
UPS input connection type 5-15P; Space saving right angled input plug
Input circuit breaker 10A
UPS Input cord length (ft.) 6
UPS Input cord length (m) 1.8
Recommended Electrical Service 15A 120V
BATTERY
Full load runtime (minutes) 3.5 min. (900w)
Half load runtime (minutes) 13 min. (450w)
DC system voltage 24V DC
Battery recharge rate (included batteries) Less than 4.5 hours from 10% to
90%
VOLTAGE REGULATION
Voltage regulation description Automatic voltage regulation (AVR)
maintains line power operation with an input voltage range of 75 to 147
Overvoltage correction Input voltages between 128 and 147 are reduced by 12%
Undervoltage correction Input voltages between 93 and 107 are boosted by 14%
Severe undervoltage correction Input voltages between 75 and 92 are boosted
by 30%
LEDS ALARMS & SWITCHES
LED Indicators Front panel LCD display
Front panel LCD display Backlighted LCD screen indicates input voltage,
5-bar battery charge level, overload, AVR, on battery and replace battery
status; LCD screen rotates for rack/tower viewing
Alarms Audible alarm indicates power-failure and low-battery conditions
Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel
switch; once silenced, alarm will re-sound to indicate low-battery status
Switches 2 Switches control off/on power status and alarm-cancel/self-test
operation; dimmer switch controls LCD brightness
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating 480
UPS AC suppression response time Instantaneous
UPS Dataline suppression 1 line TEL / DSL or 10Base T Ethernet protection
EMI / RFI AC noise suppression Yes
PHYSICAL
Installation form factors supported with included accessories 4 post 19
inch rackmount (mounting kit included); 2 post 19 inch rackmount (mounting
kit included); Tower
Included mounting accessory description Pair of mounting ears enable tower
and 2-4 post rackmount installation
Primary form factor Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth
/ inches) 3.5 x 17.2 x 10.5
UPS / Power Module dimensions in primary form factor (height x width x depth
/ cm) 8.9 x 43.8 x 26.7
Installed whole system maximum rack depth (inches) 10.5
Installed whole system maximum rack depth (cm) 26.7
Installed whole system total rack space height (rack spaces) 2U
Secondary form factor Tower
Installed whole system dimensions in secondary form factor (height x width x
depth / inches) 17.2 x 3.5 x 10.5
UPS dimensions in secondary form factor (height x width x depth / cm) 43.8 x
8.9 x 26.7
UPS / Power Module weight (lbs) 29.4
UPS / Power Module weight (kg) 13.3
UPS Shipping dimensions (height x width x depth / inches) 7.5 x 15 x 21.5
UPS Shipping dimensions (height x width x depth / cm) 19 x 38.1 x 54.6
Shipping weight (lbs) 33.4
Shipping weight (kg) 15.2
UPS housing material ABS
Cooling method Fan
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40
degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees
Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 266.1
Battery mode BTU / hr. (full load) 626.7
COMMUNICATIONS
Communications interface USB (HID enabled); DB9 Serial
Network monitoring port description Supports detailed monitoring of UPS and
site power conditions
PowerAlert software Free download from www.tripplite.com
Communications cable USB and DB9 Serial cabling included
WatchDog compatibility Supports Watchdog application, OS and hard-reboot
restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time 2-4 milliseconds
Low voltage transfer to battery power (setpoint) 75
High voltage transfer to battery power (setpoint) 147
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure) Cold-start
operation supported
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada);
Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); Meets FCC Part
68 / Industrie Canada (telecommunications); ROHS (Reduction of Hazardous
Substances)
WARRANTY
Product Warranty Period (U.S., Canada & Puerto Rico) 3 years
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000
connected equipment insurance
|